Reduce carbon emissions by 50%+ without compromising performance
-
Maximise renewable energy use by storing surplus solar or wind for demand is greatest.
-
Take control of energy costs and usage by optimising when and how energy is used.
EasyGrid BESS – because sustainable energy only delivers value when it’s used effectively
For most organisations, the challenge isn’t adopting sustainable energy - it’s making it work in practice. Renewable energy systems such as solar often generate power at the wrong time. Surplus energy is exported at low value, while demand later in the day still relies on grid supply or backup generation. Energy is available, but not when it’s needed. Costs remain exposed, and sustainability gains fall short of expectations. Battery energy storage bridges that gap. In live deployments, our EasyGrid systems have already helped organisations reduce fuel consumption and emissions by more than 50% while significantly reducing generator runtime.
By storing sustainable energy when it’s generated and releasing it when demand requires it, EasyGrid allows organisations to take control of how energy is used - reducing waste, lowering emissions and turning sustainable energy into a reliable, usable part of everyday operations.
-
Energy is captured when it’s available - From solar, grid supply or generation sources, rather than being lost or exported at low value.
-
Storage bridges the gap between supply and demand - Power is held in reserve and released when generation drops or demand increases.
-
Energy is used when it matters most - Stored energy supports peak demand periods, reducing reliance on grid electricity or backup generation.
-
Usage is controlled automatically - Intelligent energy management ensures energy is stored, prioritised and deployed efficiently without manual intervention.
The result is a sustainable energy system that is not only cleaner, but controllable - helping organisations align energy use with both operational needs and sustainability goals.
Delivering measurable reductions in fuel use, emissions and operating costs
Across deployed EasyGrid systems, Energy Solutions is already delivering measurable reductions in fuel consumption, emissions and operating costs in real-world environments.
Based on verified deployment data from 2026 deployed systems, EasyGrid is projected to help save annually:
-
Over 25 million litres of diesel.
-
More than 60,000 tonnes of CO₂ emissions.
-
More than £38 million in fuel costs.
In monitored live deployments, generator runtime has been reduced from continuous 24-hour operation to between 4–10 hours per day, with fuel usage typically reduced by more than 50%. EasyGrid systems are now deployed across organisations including JCB, Speedy Hire, Wernick Power Solutions and the Ministry of Defence.
Technical specification:
| Model variation | 14kWh | 28kWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 12 | 12 | |||
| Output power from battery power | kVA | 15 | 15 | |||
| Output voltage | VAC 1PH | 230 | 230 | |||
| Input voltage | VAC 1PH | 230 | 230 | |||
| Battery capacity | kWh | 14 | 28 | |||
| Passthrough current limit from main input | A | 63 | 63 | |||
| Battery nominal voltage | V DC | 48 | 48 | |||
| Operating ambient temperature | Deg C | -10 - +30 deg | -10 - +30 deg | |||
| Battery cooling | Forced air | Forced air | ||||
| IP rating | IP54 | IP54 | ||||
| Input connection | A | 1 x 63A 1PH | 1 x 63A 1PH | |||
| Output connection | A | 1 x 63A 1PH and 1 x 16A 1PH | 1 x 63A 1PH and 1 x 16A 1PH | |||
| PV input capacity (optional) | kWp | 5.5/11 | 5.5/11 | |||
| PV input | VAC | 65-450 | 65-450 | |||
| Noise level | dBA @7M | TBC | TBC | |||
| Weight | kg | 602 | 602 | |||
| Dimensions | D x L x H mm | 913 x 913 x 1500 | 913 x 913 x 1500 | |||
Model variation: 14kWh
| Output power from battery power | 12kW | |
| Output power from battery power | 15kVA | |
| Output voltage | 230VAC 1PH | |
| Input voltage | 230VAC 1PH | |
| Battery capacity | 14kWh | |
| Passthrough current limit from main input | 63A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| IP rating | IP54 | |
| Input connection | 1 x 63A 1PH | |
| Output connection | 1 x 63A 1PH and 1 x 16A 1PH | |
| PV input capacity (optional) | 5.5/11kWp | |
| PV input | 65-450VAC | |
| Noise level | TBC dBA @7M | |
| Weight | 602kg | |
| Dimensions (D x L x H) | 913 x 913 x 1500mm | |
Model variation: 28kWh
| Output power from battery power | 12kW | |
| Output power from battery power | 15kVA | |
| Output voltage | 230VAC 1PH | |
| Input voltage | 230VAC 1PH | |
| Battery capacity | 28kWh | |
| Passthrough current limit from main input | 63A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| IP rating | IP54 | |
| Input connection | 1 x 63A 1PH | |
| Output connection | 1 x 63A 1PH and 1 x 16A 1PH | |
| PV input capacity (optional) | 5.5/11kWp | |
| PV input | 65-450VAC | |
| Noise level | TBC dBA @7M | |
| Weight | 602kg | |
| Dimensions (D x L x H) | 913 x 913 x 1500mm | |
Technical specification:
| Model variation | 93kWh | 125kWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 60 | 60 | |||
| Output power from battery power | kVA | 60 | 60 | |||
| Output voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Aux input voltage (maintenance) | VAC 1PH | 240 | 240 | |||
| Battery capacity | kWh | 93 | 125 | |||
| Passthrough current limit from main input | A | 100 - 400 | 100 - 400 | |||
| Battery nominal voltage | V DC | 48 | 48 | |||
| Operating ambient temperature | Deg C | -10 - +35 deg | -10 - +35 deg | |||
| Battery cooling | Forced air | Forced air | ||||
| IP rating | IP54 | IP54 | ||||
| Input connection | A | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |||
| Output connection | A | 1 x 125A (others configurable) | 1 x 125A (others configurable) | |||
| PV input capacity (optional) | kWp | 5.5 or 11 | 5.5 or 11 | |||
| PV input (DC option) | VDC | 65 - 450 | 65 - 450 | |||
| Noise level | dBA @7M | TBC | TBC | |||
| Weight | kg | 2500* | 2500* | |||
| Dimensions | D x L x H mm | 1325 x 2190 x 1917 | 1325 x 2190 x 1917 | |||
Model variation: 93kWh
| Output power from battery power | 60kW | |
| Output power from battery power | 60kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Aux input voltage (maintenance) | 240VAC 1PH | |
| Battery capacity | 93kWh | |
| Passthrough current limit from main input | 100 - 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +35º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |
| Output connection | 1 x 125A (others configurable) | |
| PV input capacity (optional) | 5.5 or 11kWp | |
| PV input (DC option) | 65 - 450VDC | |
| Noise level | TBC dBA @7M | |
| Weight | 2500*kg | |
| Dimensions (D x L x H) | 1325 x 2190 x 1917mm | |
Model variation: 125kWh
| Output power from battery power | 60kW | |
| Output power from battery power | 60kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Aux input voltage (maintenance) | 240VAC 1PH | |
| Battery capacity | 125kWh | |
| Passthrough current limit from main input | 100 - 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +35º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |
| Output connection | 1 x 125A (others configurable) | |
| PV input capacity (optional) | 5.5 or 11kWp | |
| PV input (DC option) | 65 - 450VDC | |
| Noise level | TBC dBA @7M | |
| Weight | 2500*kg | |
| Dimensions (D x L x H) | 1325 x 2190 x 1917mm | |
*Weight depends on configuration.
Technical specification:
| Output power from battery power | kW | 120 | ||
| Output power from battery power | kVA | 120 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Aux input voltage | VAC 1PH | 240 | ||
| Battery capacity | kWh | 218 | ||
| Passthrough current limit from main input | A | 400 | ||
| Battery nominal voltage | V DC | 48 | ||
| Operating ambient temperature | Deg C | -10 - +30 deg | ||
| Battery cooling | Forced air | |||
| IP rating | IP54 | |||
| Input connection | A | Powersafe, 1x 32A 1PH | ||
| Output connection | A | Powersafe, 1 x 125A, 3 x 63A, 1x16a 1PH* | ||
| PV input capacity (optional) | kWp | 5.5 / 11 | ||
| PV input (DC) | VDC | 65-450 | ||
| Noise level | dBA @7M | TBC | ||
| Weight | kg | 4,200 | ||
| Dimensions | D x L x H mm | 1180 x 2944 x 2137 | ||
| Output power from battery power | 120kW | |
| Output power from battery power | 120kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | V380 / 400 / 415AC 3PH | |
| Aux input voltage | 240VAC 1PH | |
| Battery capacity | 218kWh | |
| Passthrough current limit from main input | 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | Powersafe, 1x 32A 1PH | |
| Output connection | Powersafe, 1 x 125A, 3 x 63A, 1x16a 1PH* | |
| PV input capacity (optional) | 5.5 / 11kWp | |
| PV input (DC) | 65-450VDC | |
| Noise level | TBCdBA @7M | |
| Weight | 4,200kg | |
| Dimensions (D x L x H) | 1180 x 2944 x 2137mm | |
*Output sockets can be customised
Technical specification:
| Output power from battery power | kW | 200 | ||
| Output power from battery power | kVA | 200 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 60 | ||
| Battery capacity | kWh | 249 | ||
| Passthrough current limit from main input | A | 250 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery Cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input Connection | A | 600A Powersafe | ||
| Output Connection | A | 600A Powersafe | ||
| Series Input Connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 60 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 6,282 | ||
| Dimensions | D x L x H mm | 2780 x 1950 x 2280 | ||
| Output power from battery power | 200kW | |
| Output power from battery power | 200kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 60kW | |
| Battery capacity | 249kWh | |
| Passthrough current limit from main input | 250A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery Cooling | AC - forced air | |
| IP rating | IP54 | |
| Input Connection | 600A Powersafe | |
| Output Connection | 600A Powersafe | |
| Series Input Connector | 1x 125A IEC60309 | |
| PV input capacity | 60kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 6,282kg | |
| Dimensions (D x L x H) | 2780 x 1850 x 2280mm | |
Technical specification:
| Output power from battery power | kW | 300 | ||
| Output power from battery power | kVA | 300 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 90 | ||
| Battery capacity | kWh | 374 | ||
| Passthrough current limit from main input | A | 400 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input connection | A | 2x 600A Powersafe | ||
| Output connection | A | 2x 600A Powersafe | ||
| Series input connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 110 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 9,204 | ||
| Dimensions | D x L x H mm | 3950 x 2050 x 2336 | ||
| Output power from battery power | 300kW | |
| Output power from battery power | 300kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 90kW | |
| Battery capacity | 374kWh | |
| Passthrough current limit from main input | 400A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery cooling | AC - forced air | |
| IP rating | IP54 | |
| Input connection | 2x 600A Powersafe | |
| Output connection | 2x 600A Powersafe | |
| Series input connector | 1x 125A IEC60309 | |
| PV input capacity | 110kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 9,204kg | |
| Dimensions (D x L x H) | 3950 x 2050 x 2336mm | |
Technical specification:
| Output power from battery power | kW | 400 | ||
| Output power from battery power | kVA | 400 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 80 | ||
| Battery capacity | kWh | 499 | ||
| Passthrough current limit from main input | A | 550 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input connection | A | 2x 600A Powersafe | ||
| Output connection | A | 2x 600A Powersafe | ||
| Series input connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 110 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 12,000 | ||
| Dimensions | D x L x H mm | 4650 x 2300 x 2500 | ||
| Output power from battery power | 400kW | |
| Output power from battery power | 400kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 80kW | |
| Battery capacity | 499kWh | |
| Passthrough current limit from main input | 550A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery cooling | AC - forced air | |
| IP rating | IP54 | |
| Input connection | 2x 600A Powersafe | |
| Output connection | 2x 600A Powersafe | |
| Series input connector | 1x 125A IEC60309 | |
| PV input capacity | 110kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 12,000kg | |
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | |
Technical specification:
| Model Variation | 624kWh | 1MWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 500 | 500 | |||
| Output power from battery power | kVA | 500 | 500 | |||
| Output voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Series input max capacity | kW | 80 | 80 | |||
| Battery capacity | kWh | 624 | 1040 | |||
| Passthrough current limit from main input | A | 630 | 630 | |||
| Battery nominal voltage | V DC | 832 | 832 | |||
| Operating ambient temperature | Deg C | -30 - +50 deg | -30 - +50 deg | |||
| Battery Cooling | AC - forced air | Liquid cooled | ||||
| IP rating | IP54 | IP54 | ||||
| Input Connection | A | 2x 600A Powersafe | 2x 600A Powersafe | |||
| Output Connection | A | 2x 600A Powersafe | 2x 600A Powersafe | |||
| Series Input Connector | A | 1x 125A IEC60309 | 1x 125A IEC60309 | |||
| PV input capacity | kWp | 110 | 110 | |||
| PV min - max OCV | VAC | 200-1000 | 200-1000 | |||
| Noise level | dBA @7M | 58 | 58 | |||
| Weight | kg | 14,194 | 14,194 | |||
| Dimensions | D x L x H mm | 4650 x 2300 x 2500 | 4650 x 2300 x 2500 | |||
Model variation: 624kWh
| Output power from battery power | 500kW | ||
| Output power from battery power | 500kVA | ||
| Output voltage | 380 / 400 / 415VAC 3PH | ||
| Input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input max capacity | 80kW | ||
| Battery capacity | 624kWh | ||
| Passthrough current limit from main input | 630A | ||
| Battery nominal voltage | 832V DC | ||
| Operating ambient temperature | -30 - +50ºC | ||
| Battery Cooling | AC - forced air | ||
| IP rating | IP54 | ||
| Input Connection | 2x 600A Powersafe | ||
| Output Connection | 2x 600A Powersafe | ||
| Series Input Connector | 1x 125A IEC60309 | ||
| PV input capacity | 110kWp | ||
| PV min - max OCV | 200-1000VAC | ||
| Noise level | 58dBA @7M | ||
| Weight | 14,194kg | ||
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | ||
Model variation: 1MW
| Output power from battery power | 500kW | ||
| Output power from battery power | 500kVA | ||
| Output voltage | 380 / 400 / 415VAC 3PH | ||
| Input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input max capacity | 80kW | ||
| Battery capacity | 1040kWh | ||
| Passthrough current limit from main input | 630A | ||
| Battery nominal voltage | 832V DC | ||
| Operating ambient temperature | -30 - +50ºC | ||
| Battery Cooling | Liquid cooled | ||
| IP rating | IP54 | ||
| Input Connection | 2x 600A Powersafe | ||
| Output Connection | 2x 600A Powersafe | ||
| Series Input Connector | 1x 125A IEC60309 | ||
| PV input capacity | 110kWp | ||
| PV min - max OCV | 200-1000VAC | ||
| Noise level | 58dBA @7M | ||
| Weight | 14,194kg | ||
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | ||
Technical specification:
| Model variation | 14kWh | 28kWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 12 | 12 | |||
| Output power from battery power | kVA | 15 | 15 | |||
| Output voltage | VAC 1PH | 230 | 230 | |||
| Input voltage | VAC 1PH | 230 | 230 | |||
| Battery capacity | kWh | 14 | 28 | |||
| Passthrough current limit from main input | A | 63 | 63 | |||
| Battery nominal voltage | V DC | 48 | 48 | |||
| Operating ambient temperature | Deg C | -10 - +30 deg | -10 - +30 deg | |||
| Battery cooling | Forced air | Forced air | ||||
| IP rating | IP54 | IP54 | ||||
| Input connection | A | 1 x 63A 1PH | 1 x 63A 1PH | |||
| Output connection | A | 1 x 63A 1PH and 1 x 16A 1PH | 1 x 63A 1PH and 1 x 16A 1PH | |||
| PV input capacity (optional) | kWp | 5.5/11 | 5.5/11 | |||
| PV input | VAC | 65-450 | 65-450 | |||
| Noise level | dBA @7M | TBC | TBC | |||
| Weight | kg | 602 | 602 | |||
| Dimensions | D x L x H mm | 913 x 913 x 1500 | 913 x 913 x 1500 | |||
Model variation: 14kWh
| Output power from battery power | 12kW | |
| Output power from battery power | 15kVA | |
| Output voltage | 230VAC 1PH | |
| Input voltage | 230VAC 1PH | |
| Battery capacity | 14kWh | |
| Passthrough current limit from main input | 63A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| IP rating | IP54 | |
| Input connection | 1 x 63A 1PH | |
| Output connection | 1 x 63A 1PH and 1 x 16A 1PH | |
| PV input capacity (optional) | 5.5/11kWp | |
| PV input | 65-450VAC | |
| Noise level | TBC dBA @7M | |
| Weight | 602kg | |
| Dimensions (D x L x H) | 913 x 913 x 1500mm | |
Model variation: 28kWh
| Output power from battery power | 12kW | |
| Output power from battery power | 15kVA | |
| Output voltage | 230VAC 1PH | |
| Input voltage | 230VAC 1PH | |
| Battery capacity | 28kWh | |
| Passthrough current limit from main input | 63A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| IP rating | IP54 | |
| Input connection | 1 x 63A 1PH | |
| Output connection | 1 x 63A 1PH and 1 x 16A 1PH | |
| PV input capacity (optional) | 5.5/11kWp | |
| PV input | 65-450VAC | |
| Noise level | TBC dBA @7M | |
| Weight | 602kg | |
| Dimensions (D x L x H) | 913 x 913 x 1500mm | |
Technical specification:
| Model variation | 93kWh | 125kWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 60 | 60 | |||
| Output power from battery power | kVA | 60 | 60 | |||
| Output voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Aux input voltage (maintenance) | VAC 1PH | 240 | 240 | |||
| Battery capacity | kWh | 93 | 125 | |||
| Passthrough current limit from main input | A | 100 - 400 | 100 - 400 | |||
| Battery nominal voltage | V DC | 48 | 48 | |||
| Operating ambient temperature | Deg C | -10 - +35 deg | -10 - +35 deg | |||
| Battery cooling | Forced air | Forced air | ||||
| IP rating | IP54 | IP54 | ||||
| Input connection | A | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |||
| Output connection | A | 1 x 125A (others configurable) | 1 x 125A (others configurable) | |||
| PV input capacity (optional) | kWp | 5.5 or 11 | 5.5 or 11 | |||
| PV input (DC option) | VDC | 65 - 450 | 65 - 450 | |||
| Noise level | dBA @7M | TBC | TBC | |||
| Weight | kg | 2500* | 2500* | |||
| Dimensions | D x L x H mm | 1325 x 2190 x 1917 | 1325 x 2190 x 1917 | |||
Model variation: 93kWh
| Output power from battery power | 60kW | |
| Output power from battery power | 60kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Aux input voltage (maintenance) | 240VAC 1PH | |
| Battery capacity | 93kWh | |
| Passthrough current limit from main input | 100 - 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +35º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |
| Output connection | 1 x 125A (others configurable) | |
| PV input capacity (optional) | 5.5 or 11kWp | |
| PV input (DC option) | 65 - 450VDC | |
| Noise level | TBC dBA @7M | |
| Weight | 2500*kg | |
| Dimensions (D x L x H) | 1325 x 2190 x 1917mm | |
Model variation: 125kWh
| Output power from battery power | 60kW | |
| Output power from battery power | 60kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Aux input voltage (maintenance) | 240VAC 1PH | |
| Battery capacity | 125kWh | |
| Passthrough current limit from main input | 100 - 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +35º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |
| Output connection | 1 x 125A (others configurable) | |
| PV input capacity (optional) | 5.5 or 11kWp | |
| PV input (DC option) | 65 - 450VDC | |
| Noise level | TBC dBA @7M | |
| Weight | 2500*kg | |
| Dimensions (D x L x H) | 1325 x 2190 x 1917mm | |
*Weight depends on configuration.
Technical specification:
| Output power from battery power | kW | 120 | ||
| Output power from battery power | kVA | 120 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Aux input voltage | VAC 1PH | 240 | ||
| Battery capacity | kWh | 218 | ||
| Passthrough current limit from main input | A | 400 | ||
| Battery nominal voltage | V DC | 48 | ||
| Operating ambient temperature | Deg C | -10 - +30 deg | ||
| Battery cooling | Forced air | |||
| IP rating | IP54 | |||
| Input connection | A | Powersafe, 1x 32A 1PH | ||
| Output connection | A | Powersafe, 1 x 125A, 3 x 63A, 1x16a 1PH* | ||
| PV input capacity (optional) | kWp | 5.5 / 11 | ||
| PV input (DC) | VDC | 65-450 | ||
| Noise level | dBA @7M | TBC | ||
| Weight | kg | 4,200 | ||
| Dimensions | D x L x H mm | 1180 x 2944 x 2137 | ||
| Output power from battery power | 120kW | |
| Output power from battery power | 120kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | V380 / 400 / 415AC 3PH | |
| Aux input voltage | 240VAC 1PH | |
| Battery capacity | 218kWh | |
| Passthrough current limit from main input | 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | Powersafe, 1x 32A 1PH | |
| Output connection | Powersafe, 1 x 125A, 3 x 63A, 1x16a 1PH* | |
| PV input capacity (optional) | 5.5 / 11kWp | |
| PV input (DC) | 65-450VDC | |
| Noise level | TBCdBA @7M | |
| Weight | 4,200kg | |
| Dimensions (D x L x H) | 1180 x 2944 x 2137mm | |
*Output sockets can be customised
Technical specification:
| Output power from battery power | kW | 200 | ||
| Output power from battery power | kVA | 200 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 60 | ||
| Battery capacity | kWh | 249 | ||
| Passthrough current limit from main input | A | 250 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery Cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input Connection | A | 600A Powersafe | ||
| Output Connection | A | 600A Powersafe | ||
| Series Input Connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 60 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 6,282 | ||
| Dimensions | D x L x H mm | 2780 x 1950 x 2280 | ||
| Output power from battery power | 200kW | |
| Output power from battery power | 200kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 60kW | |
| Battery capacity | 249kWh | |
| Passthrough current limit from main input | 250A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery Cooling | AC - forced air | |
| IP rating | IP54 | |
| Input Connection | 600A Powersafe | |
| Output Connection | 600A Powersafe | |
| Series Input Connector | 1x 125A IEC60309 | |
| PV input capacity | 60kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 6,282kg | |
| Dimensions (D x L x H) | 2780 x 1850 x 2280mm | |
Technical specification:
| Output power from battery power | kW | 300 | ||
| Output power from battery power | kVA | 300 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 90 | ||
| Battery capacity | kWh | 374 | ||
| Passthrough current limit from main input | A | 400 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input connection | A | 2x 600A Powersafe | ||
| Output connection | A | 2x 600A Powersafe | ||
| Series input connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 110 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 9,204 | ||
| Dimensions | D x L x H mm | 3950 x 2050 x 2336 | ||
| Output power from battery power | 300kW | |
| Output power from battery power | 300kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 90kW | |
| Battery capacity | 374kWh | |
| Passthrough current limit from main input | 400A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery cooling | AC - forced air | |
| IP rating | IP54 | |
| Input connection | 2x 600A Powersafe | |
| Output connection | 2x 600A Powersafe | |
| Series input connector | 1x 125A IEC60309 | |
| PV input capacity | 110kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 9,204kg | |
| Dimensions (D x L x H) | 3950 x 2050 x 2336mm | |
Technical specification:
| Output power from battery power | kW | 400 | ||
| Output power from battery power | kVA | 400 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 80 | ||
| Battery capacity | kWh | 499 | ||
| Passthrough current limit from main input | A | 550 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input connection | A | 2x 600A Powersafe | ||
| Output connection | A | 2x 600A Powersafe | ||
| Series input connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 110 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 12,000 | ||
| Dimensions | D x L x H mm | 4650 x 2300 x 2500 | ||
| Output power from battery power | 400kW | |
| Output power from battery power | 400kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 80kW | |
| Battery capacity | 499kWh | |
| Passthrough current limit from main input | 550A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery cooling | AC - forced air | |
| IP rating | IP54 | |
| Input connection | 2x 600A Powersafe | |
| Output connection | 2x 600A Powersafe | |
| Series input connector | 1x 125A IEC60309 | |
| PV input capacity | 110kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 12,000kg | |
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | |
Technical specification:
| Model Variation | 624kWh | 1MWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 500 | 500 | |||
| Output power from battery power | kVA | 500 | 500 | |||
| Output voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Series input max capacity | kW | 80 | 80 | |||
| Battery capacity | kWh | 624 | 1040 | |||
| Passthrough current limit from main input | A | 630 | 630 | |||
| Battery nominal voltage | V DC | 832 | 832 | |||
| Operating ambient temperature | Deg C | -30 - +50 deg | -30 - +50 deg | |||
| Battery Cooling | AC - forced air | Liquid cooled | ||||
| IP rating | IP54 | IP54 | ||||
| Input Connection | A | 2x 600A Powersafe | 2x 600A Powersafe | |||
| Output Connection | A | 2x 600A Powersafe | 2x 600A Powersafe | |||
| Series Input Connector | A | 1x 125A IEC60309 | 1x 125A IEC60309 | |||
| PV input capacity | kWp | 110 | 110 | |||
| PV min - max OCV | VAC | 200-1000 | 200-1000 | |||
| Noise level | dBA @7M | 58 | 58 | |||
| Weight | kg | 14,194 | 14,194 | |||
| Dimensions | D x L x H mm | 4650 x 2300 x 2500 | 4650 x 2300 x 2500 | |||
Model variation: 624kWh
| Output power from battery power | 500kW | ||
| Output power from battery power | 500kVA | ||
| Output voltage | 380 / 400 / 415VAC 3PH | ||
| Input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input max capacity | 80kW | ||
| Battery capacity | 624kWh | ||
| Passthrough current limit from main input | 630A | ||
| Battery nominal voltage | 832V DC | ||
| Operating ambient temperature | -30 - +50ºC | ||
| Battery Cooling | AC - forced air | ||
| IP rating | IP54 | ||
| Input Connection | 2x 600A Powersafe | ||
| Output Connection | 2x 600A Powersafe | ||
| Series Input Connector | 1x 125A IEC60309 | ||
| PV input capacity | 110kWp | ||
| PV min - max OCV | 200-1000VAC | ||
| Noise level | 58dBA @7M | ||
| Weight | 14,194kg | ||
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | ||
Model variation: 1MW
| Output power from battery power | 500kW | ||
| Output power from battery power | 500kVA | ||
| Output voltage | 380 / 400 / 415VAC 3PH | ||
| Input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input max capacity | 80kW | ||
| Battery capacity | 1040kWh | ||
| Passthrough current limit from main input | 630A | ||
| Battery nominal voltage | 832V DC | ||
| Operating ambient temperature | -30 - +50ºC | ||
| Battery Cooling | Liquid cooled | ||
| IP rating | IP54 | ||
| Input Connection | 2x 600A Powersafe | ||
| Output Connection | 2x 600A Powersafe | ||
| Series Input Connector | 1x 125A IEC60309 | ||
| PV input capacity | 110kWp | ||
| PV min - max OCV | 200-1000VAC | ||
| Noise level | 58dBA @7M | ||
| Weight | 14,194kg | ||
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | ||
Typical applications for sustainable battery energy storage systems
Our solutions are designed for organisations looking to actively reduce emissions while maintaining reliable, efficient operations.
-
Commercial and industrial facilities
Reduce operational emissions, manage energy demand and improve efficiency across buildings, production sites and estates.
-
Renewable energy projects
Store excess solar or wind generation and use it when production drops or demand increases.
-
Public sector and infrastructure
Support sustainability targets for schools, hospitals, transport systems and municipal facilities.
-
Corporate net zero initiatives
Enable organisations to reduce carbon footprint while maintaining operational resilience and cost control.
-
Community and estate-based energy systems
Provide sustainable power across distributed sites, remote facilities and mixed-use environments.
In each case, the challenge is the same: turning renewable generation into usable, controllable energy that supports real-world operations.
Trusted suppliers of battery energy storage solutions (BESS) to
How battery storage turns sustainable energy into measurable performance
Our systems are built around a simple principle: sustainability only delivers value when energy is controlled, not just generated. Without storage, renewable energy often remains disconnected from real operational demand. Generation doesn’t align with usage, surplus energy is lost or undervalued, and organisations remain exposed to grid costs and inefficiencies. Battery energy storage changes that. It allows organisations to:
-
Use more of the energy generated, rather than exporting it at low value
-
Reduce reliance on carbon-intensive supply, without compromising performance
-
Align energy use with operational demand, not generation timing
-
Track and manage energy performance in real time
The result is sustainability that works in practice - delivering measurable reductions in emissions, improved efficiency and greater control over energy use.
Advanced battery energy storage for sustainable energy systems
Our systems combine proven battery technology with intelligent control to maximise performance and minimise environmental impact:
Lithium-ion (LiFePO₄) battery storage for long cycle life and high efficiency.
Seamless integration with solar, wind and hybrid energy systems.
Smart energy management to optimise charging, storage and usage.
Peak shaving and load management to reduce demand spikes.
Remote monitoring for full visibility and performance tracking.
Systems are scalable and adaptable, allowing organisations to align energy infrastructure with long-term sustainability and operational goals.
UK-engineered systems built for real-world sustainability
Energy Solutions has more than 30 years’ experience designing and delivering energy systems that work in practice. We focus on real-world performance – and that means sustainability improvements which translate into measurable reductions in cost, emissions and operational risk. From system design through to deployment and optimisation, our approach is built around delivering energy solutions that are reliable, efficient and commercially viable.
From specification to deployment: How it works
Step 1 - Understand your energy profile and goals
We start by analysing how energy is used across your operation – including demand patterns, peak loads and renewable generation potential – to identify the most effective solution.
Step 2 - Design a system that delivers measurable impact
We configure a battery-led energy system that maximises renewable use, reduces waste and ensures reliable, efficient power tailored to your needs.
Step 3 - Optimise performance over time
With monitoring, support and ongoing optimisation, we ensure your system continues to deliver against both sustainability targets and commercial objectives.
What’s at stake when energy isn’t managed sustainably
Without effective energy storage, organisations face ongoing inefficiencies in spite of efforts to operate more sustainably. Renewable energy is wasted. Costs remain exposed to volatile pricing. Carbon reduction targets become difficult to achieve in practice. Battery-led energy storage changes that - turning sustainability from a theoretical goal into a controllable, measurable outcome that supports both environmental and commercial performance.