Transportable battery energy storage solutions UK for construction and infrastructure projects
When your project needs reliable power without relying solely on diesel generators, transportable and intelligent battery energy storage is the smarter choice. Our units are designed for the toughest commercial environments, from construction sites and festivals to defence and humanitarian operations.
Rugged design
Built for industrial and outdoor conditions
Hybrid flexibility
Integrates with generators or renewables for maximum efficiency
Quiet, clean performance
Meet noise restrictions and sustainability goals with ease

Technical specification:
| Model variation | 14kWh | 28kWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 12 | 12 | |||
| Output power from battery power | kVA | 15 | 15 | |||
| Output voltage | VAC 1PH | 230 | 230 | |||
| Input voltage | VAC 1PH | 230 | 230 | |||
| Battery capacity | kWh | 14 | 28 | |||
| Passthrough current limit from main input | A | 63 | 63 | |||
| Battery nominal voltage | V DC | 48 | 48 | |||
| Operating ambient temperature | Deg C | -10 - +30 deg | -10 - +30 deg | |||
| Battery cooling | Forced air | Forced air | ||||
| IP rating | IP54 | IP54 | ||||
| Input connection | A | 1 x 63A 1PH | 1 x 63A 1PH | |||
| Output connection | A | 1 x 63A 1PH and 1 x 16A 1PH | 1 x 63A 1PH and 1 x 16A 1PH | |||
| PV input capacity (optional) | kWp | 5.5/11 | 5.5/11 | |||
| PV input | VAC | 65-450 | 65-450 | |||
| Noise level | dBA @7M | TBC | TBC | |||
| Weight | kg | 602 | 602 | |||
| Dimensions | D x L x H mm | 913 x 913 x 1500 | 913 x 913 x 1500 | |||
Model variation: 14kWh
| Output power from battery power | 12kW | |
| Output power from battery power | 15kVA | |
| Output voltage | 230VAC 1PH | |
| Input voltage | 230VAC 1PH | |
| Battery capacity | 14kWh | |
| Passthrough current limit from main input | 63A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| IP rating | IP54 | |
| Input connection | 1 x 63A 1PH | |
| Output connection | 1 x 63A 1PH and 1 x 16A 1PH | |
| PV input capacity (optional) | 5.5/11kWp | |
| PV input | 65-450VAC | |
| Noise level | TBC dBA @7M | |
| Weight | 602kg | |
| Dimensions (D x L x H) | 913 x 913 x 1500mm | |
Model variation: 28kWh
| Output power from battery power | 12kW | |
| Output power from battery power | 15kVA | |
| Output voltage | 230VAC 1PH | |
| Input voltage | 230VAC 1PH | |
| Battery capacity | 28kWh | |
| Passthrough current limit from main input | 63A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| IP rating | IP54 | |
| Input connection | 1 x 63A 1PH | |
| Output connection | 1 x 63A 1PH and 1 x 16A 1PH | |
| PV input capacity (optional) | 5.5/11kWp | |
| PV input | 65-450VAC | |
| Noise level | TBC dBA @7M | |
| Weight | 602kg | |
| Dimensions (D x L x H) | 913 x 913 x 1500mm | |

Technical specification:
| Model variation | 93kWh | 125kWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 60 | 60 | |||
| Output power from battery power | kVA | 60 | 60 | |||
| Output voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Aux input voltage (maintenance) | VAC 1PH | 240 | 240 | |||
| Battery capacity | kWh | 93 | 125 | |||
| Passthrough current limit from main input | A | 100 - 400 | 100 - 400 | |||
| Battery nominal voltage | V DC | 48 | 48 | |||
| Operating ambient temperature | Deg C | -10 - +35 deg | -10 - +35 deg | |||
| Battery cooling | Forced air | Forced air | ||||
| IP rating | IP54 | IP54 | ||||
| Input connection | A | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |||
| Output connection | A | 1 x 125A (others configurable) | 1 x 125A (others configurable) | |||
| PV input capacity (optional) | kWp | 5.5 or 11 | 5.5 or 11 | |||
| PV input (DC option) | VDC | 65 - 450 | 65 - 450 | |||
| Noise level | dBA @7M | TBC | TBC | |||
| Weight | kg | 2500* | 2500* | |||
| Dimensions | D x L x H mm | 1325 x 2190 x 1917 | 1325 x 2190 x 1917 | |||
Model variation: 93kWh
| Output power from battery power | 60kW | |
| Output power from battery power | 60kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Aux input voltage (maintenance) | 240VAC 1PH | |
| Battery capacity | 93kWh | |
| Passthrough current limit from main input | 100 - 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +35º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |
| Output connection | 1 x 125A (others configurable) | |
| PV input capacity (optional) | 5.5 or 11kWp | |
| PV input (DC option) | 65 - 450VDC | |
| Noise level | TBC dBA @7M | |
| Weight | 2500*kg | |
| Dimensions (D x L x H) | 1325 x 2190 x 1917mm | |
Model variation: 125kWh
| Output power from battery power | 60kW | |
| Output power from battery power | 60kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Aux input voltage (maintenance) | 240VAC 1PH | |
| Battery capacity | 125kWh | |
| Passthrough current limit from main input | 100 - 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +35º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |
| Output connection | 1 x 125A (others configurable) | |
| PV input capacity (optional) | 5.5 or 11kWp | |
| PV input (DC option) | 65 - 450VDC | |
| Noise level | TBC dBA @7M | |
| Weight | 2500*kg | |
| Dimensions (D x L x H) | 1325 x 2190 x 1917mm | |
*Weight depends on configuration.

Technical specification:
| Output power from battery power | kW | 120 | ||
| Output power from battery power | kVA | 120 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Aux input voltage | VAC 1PH | 240 | ||
| Battery capacity | kWh | 218 | ||
| Passthrough current limit from main input | A | 400 | ||
| Battery nominal voltage | V DC | 48 | ||
| Operating ambient temperature | Deg C | -10 - +30 deg | ||
| Battery cooling | Forced air | |||
| IP rating | IP54 | |||
| Input connection | A | Powersafe, 1x 32A 1PH | ||
| Output connection | A | Powersafe, 1 x 125A, 3 x 63A, 1x16a 1PH* | ||
| PV input capacity (optional) | kWp | 5.5 / 11 | ||
| PV input (DC) | VDC | 65-450 | ||
| Noise level | dBA @7M | TBC | ||
| Weight | kg | 4,200 | ||
| Dimensions | D x L x H mm | 1180 x 2944 x 2137 | ||
| Output power from battery power | 120kW | |
| Output power from battery power | 120kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | V380 / 400 / 415AC 3PH | |
| Aux input voltage | 240VAC 1PH | |
| Battery capacity | 218kWh | |
| Passthrough current limit from main input | 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | Powersafe, 1x 32A 1PH | |
| Output connection | Powersafe, 1 x 125A, 3 x 63A, 1x16a 1PH* | |
| PV input capacity (optional) | 5.5 / 11kWp | |
| PV input (DC) | 65-450VDC | |
| Noise level | TBCdBA @7M | |
| Weight | 4,200kg | |
| Dimensions (D x L x H) | 1180 x 2944 x 2137mm | |
*Output sockets can be customised


Technical specification:
| Output power from battery power | kW | 200 | ||
| Output power from battery power | kVA | 200 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 60 | ||
| Battery capacity | kWh | 249 | ||
| Passthrough current limit from main input | A | 250 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery Cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input Connection | A | 600A Powersafe | ||
| Output Connection | A | 600A Powersafe | ||
| Series Input Connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 60 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 6,282 | ||
| Dimensions | D x L x H mm | 2780 x 1950 x 2280 | ||
| Output power from battery power | 200kW | |
| Output power from battery power | 200kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 60kW | |
| Battery capacity | 249kWh | |
| Passthrough current limit from main input | 250A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery Cooling | AC - forced air | |
| IP rating | IP54 | |
| Input Connection | 600A Powersafe | |
| Output Connection | 600A Powersafe | |
| Series Input Connector | 1x 125A IEC60309 | |
| PV input capacity | 60kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 6,282kg | |
| Dimensions (D x L x H) | 2780 x 1850 x 2280mm | |


Technical specification:
| Output power from battery power | kW | 300 | ||
| Output power from battery power | kVA | 300 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 90 | ||
| Battery capacity | kWh | 374 | ||
| Passthrough current limit from main input | A | 400 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input connection | A | 2x 600A Powersafe | ||
| Output connection | A | 2x 600A Powersafe | ||
| Series input connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 110 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 9,204 | ||
| Dimensions | D x L x H mm | 3950 x 2050 x 2336 | ||
| Output power from battery power | 300kW | |
| Output power from battery power | 300kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 90kW | |
| Battery capacity | 374kWh | |
| Passthrough current limit from main input | 400A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery cooling | AC - forced air | |
| IP rating | IP54 | |
| Input connection | 2x 600A Powersafe | |
| Output connection | 2x 600A Powersafe | |
| Series input connector | 1x 125A IEC60309 | |
| PV input capacity | 110kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 9,204kg | |
| Dimensions (D x L x H) | 3950 x 2050 x 2336mm | |


Technical specification:
| Output power from battery power | kW | 400 | ||
| Output power from battery power | kVA | 400 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 80 | ||
| Battery capacity | kWh | 499 | ||
| Passthrough current limit from main input | A | 550 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input connection | A | 2x 600A Powersafe | ||
| Output connection | A | 2x 600A Powersafe | ||
| Series input connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 110 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 12,000 | ||
| Dimensions | D x L x H mm | 4650 x 2300 x 2500 | ||
| Output power from battery power | 400kW | |
| Output power from battery power | 400kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 80kW | |
| Battery capacity | 499kWh | |
| Passthrough current limit from main input | 550A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery cooling | AC - forced air | |
| IP rating | IP54 | |
| Input connection | 2x 600A Powersafe | |
| Output connection | 2x 600A Powersafe | |
| Series input connector | 1x 125A IEC60309 | |
| PV input capacity | 110kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 12,000kg | |
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | |

Technical specification:
| Model Variation | 624kWh | 1MWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 500 | 500 | |||
| Output power from battery power | kVA | 500 | 500 | |||
| Output voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Series input max capacity | kW | 80 | 80 | |||
| Battery capacity | kWh | 624 | 1040 | |||
| Passthrough current limit from main input | A | 630 | 630 | |||
| Battery nominal voltage | V DC | 832 | 832 | |||
| Operating ambient temperature | Deg C | -30 - +50 deg | -30 - +50 deg | |||
| Battery Cooling | AC - forced air | Liquid cooled | ||||
| IP rating | IP54 | IP54 | ||||
| Input Connection | A | 2x 600A Powersafe | 2x 600A Powersafe | |||
| Output Connection | A | 2x 600A Powersafe | 2x 600A Powersafe | |||
| Series Input Connector | A | 1x 125A IEC60309 | 1x 125A IEC60309 | |||
| PV input capacity | kWp | 110 | 110 | |||
| PV min - max OCV | VAC | 200-1000 | 200-1000 | |||
| Noise level | dBA @7M | 58 | 58 | |||
| Weight | kg | 14,194 | 14,194 | |||
| Dimensions | D x L x H mm | 4650 x 2300 x 2500 | 4650 x 2300 x 2500 | |||
Model variation: 624kWh
| Output power from battery power | 500kW | ||
| Output power from battery power | 500kVA | ||
| Output voltage | 380 / 400 / 415VAC 3PH | ||
| Input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input max capacity | 80kW | ||
| Battery capacity | 624kWh | ||
| Passthrough current limit from main input | 630A | ||
| Battery nominal voltage | 832V DC | ||
| Operating ambient temperature | -30 - +50ºC | ||
| Battery Cooling | AC - forced air | ||
| IP rating | IP54 | ||
| Input Connection | 2x 600A Powersafe | ||
| Output Connection | 2x 600A Powersafe | ||
| Series Input Connector | 1x 125A IEC60309 | ||
| PV input capacity | 110kWp | ||
| PV min - max OCV | 200-1000VAC | ||
| Noise level | 58dBA @7M | ||
| Weight | 14,194kg | ||
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | ||
Model variation: 1MW
| Output power from battery power | 500kW | ||
| Output power from battery power | 500kVA | ||
| Output voltage | 380 / 400 / 415VAC 3PH | ||
| Input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input max capacity | 80kW | ||
| Battery capacity | 1040kWh | ||
| Passthrough current limit from main input | 630A | ||
| Battery nominal voltage | 832V DC | ||
| Operating ambient temperature | -30 - +50ºC | ||
| Battery Cooling | Liquid cooled | ||
| IP rating | IP54 | ||
| Input Connection | 2x 600A Powersafe | ||
| Output Connection | 2x 600A Powersafe | ||
| Series Input Connector | 1x 125A IEC60309 | ||
| PV input capacity | 110kWp | ||
| PV min - max OCV | 200-1000VAC | ||
| Noise level | 58dBA @7M | ||
| Weight | 14,194kg | ||
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | ||

Technical specification:
| Model variation | 14kWh | 28kWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 12 | 12 | |||
| Output power from battery power | kVA | 15 | 15 | |||
| Output voltage | VAC 1PH | 230 | 230 | |||
| Input voltage | VAC 1PH | 230 | 230 | |||
| Battery capacity | kWh | 14 | 28 | |||
| Passthrough current limit from main input | A | 63 | 63 | |||
| Battery nominal voltage | V DC | 48 | 48 | |||
| Operating ambient temperature | Deg C | -10 - +30 deg | -10 - +30 deg | |||
| Battery cooling | Forced air | Forced air | ||||
| IP rating | IP54 | IP54 | ||||
| Input connection | A | 1 x 63A 1PH | 1 x 63A 1PH | |||
| Output connection | A | 1 x 63A 1PH and 1 x 16A 1PH | 1 x 63A 1PH and 1 x 16A 1PH | |||
| PV input capacity (optional) | kWp | 5.5/11 | 5.5/11 | |||
| PV input | VAC | 65-450 | 65-450 | |||
| Noise level | dBA @7M | TBC | TBC | |||
| Weight | kg | 602 | 602 | |||
| Dimensions | D x L x H mm | 913 x 913 x 1500 | 913 x 913 x 1500 | |||
Model variation: 14kWh
| Output power from battery power | 12kW | |
| Output power from battery power | 15kVA | |
| Output voltage | 230VAC 1PH | |
| Input voltage | 230VAC 1PH | |
| Battery capacity | 14kWh | |
| Passthrough current limit from main input | 63A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| IP rating | IP54 | |
| Input connection | 1 x 63A 1PH | |
| Output connection | 1 x 63A 1PH and 1 x 16A 1PH | |
| PV input capacity (optional) | 5.5/11kWp | |
| PV input | 65-450VAC | |
| Noise level | TBC dBA @7M | |
| Weight | 602kg | |
| Dimensions (D x L x H) | 913 x 913 x 1500mm | |
Model variation: 28kWh
| Output power from battery power | 12kW | |
| Output power from battery power | 15kVA | |
| Output voltage | 230VAC 1PH | |
| Input voltage | 230VAC 1PH | |
| Battery capacity | 28kWh | |
| Passthrough current limit from main input | 63A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| IP rating | IP54 | |
| Input connection | 1 x 63A 1PH | |
| Output connection | 1 x 63A 1PH and 1 x 16A 1PH | |
| PV input capacity (optional) | 5.5/11kWp | |
| PV input | 65-450VAC | |
| Noise level | TBC dBA @7M | |
| Weight | 602kg | |
| Dimensions (D x L x H) | 913 x 913 x 1500mm | |

Technical specification:
| Model variation | 93kWh | 125kWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 60 | 60 | |||
| Output power from battery power | kVA | 60 | 60 | |||
| Output voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Aux input voltage (maintenance) | VAC 1PH | 240 | 240 | |||
| Battery capacity | kWh | 93 | 125 | |||
| Passthrough current limit from main input | A | 100 - 400 | 100 - 400 | |||
| Battery nominal voltage | V DC | 48 | 48 | |||
| Operating ambient temperature | Deg C | -10 - +35 deg | -10 - +35 deg | |||
| Battery cooling | Forced air | Forced air | ||||
| IP rating | IP54 | IP54 | ||||
| Input connection | A | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |||
| Output connection | A | 1 x 125A (others configurable) | 1 x 125A (others configurable) | |||
| PV input capacity (optional) | kWp | 5.5 or 11 | 5.5 or 11 | |||
| PV input (DC option) | VDC | 65 - 450 | 65 - 450 | |||
| Noise level | dBA @7M | TBC | TBC | |||
| Weight | kg | 2500* | 2500* | |||
| Dimensions | D x L x H mm | 1325 x 2190 x 1917 | 1325 x 2190 x 1917 | |||
Model variation: 93kWh
| Output power from battery power | 60kW | |
| Output power from battery power | 60kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Aux input voltage (maintenance) | 240VAC 1PH | |
| Battery capacity | 93kWh | |
| Passthrough current limit from main input | 100 - 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +35º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |
| Output connection | 1 x 125A (others configurable) | |
| PV input capacity (optional) | 5.5 or 11kWp | |
| PV input (DC option) | 65 - 450VDC | |
| Noise level | TBC dBA @7M | |
| Weight | 2500*kg | |
| Dimensions (D x L x H) | 1325 x 2190 x 1917mm | |
Model variation: 125kWh
| Output power from battery power | 60kW | |
| Output power from battery power | 60kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Aux input voltage (maintenance) | 240VAC 1PH | |
| Battery capacity | 125kWh | |
| Passthrough current limit from main input | 100 - 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +35º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | 1 x 400A 3PH, 1 x 125A 3PH, 1 x 16A 1PH | |
| Output connection | 1 x 125A (others configurable) | |
| PV input capacity (optional) | 5.5 or 11kWp | |
| PV input (DC option) | 65 - 450VDC | |
| Noise level | TBC dBA @7M | |
| Weight | 2500*kg | |
| Dimensions (D x L x H) | 1325 x 2190 x 1917mm | |
*Weight depends on configuration.

Technical specification:
| Output power from battery power | kW | 120 | ||
| Output power from battery power | kVA | 120 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Aux input voltage | VAC 1PH | 240 | ||
| Battery capacity | kWh | 218 | ||
| Passthrough current limit from main input | A | 400 | ||
| Battery nominal voltage | V DC | 48 | ||
| Operating ambient temperature | Deg C | -10 - +30 deg | ||
| Battery cooling | Forced air | |||
| IP rating | IP54 | |||
| Input connection | A | Powersafe, 1x 32A 1PH | ||
| Output connection | A | Powersafe, 1 x 125A, 3 x 63A, 1x16a 1PH* | ||
| PV input capacity (optional) | kWp | 5.5 / 11 | ||
| PV input (DC) | VDC | 65-450 | ||
| Noise level | dBA @7M | TBC | ||
| Weight | kg | 4,200 | ||
| Dimensions | D x L x H mm | 1180 x 2944 x 2137 | ||
| Output power from battery power | 120kW | |
| Output power from battery power | 120kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | V380 / 400 / 415AC 3PH | |
| Aux input voltage | 240VAC 1PH | |
| Battery capacity | 218kWh | |
| Passthrough current limit from main input | 400A | |
| Battery nominal voltage | 48V DC | |
| Operating ambient temperature | -10 - +30º C | |
| Battery cooling | Forced air | |
| IP rating | IP54 | |
| Input connection | Powersafe, 1x 32A 1PH | |
| Output connection | Powersafe, 1 x 125A, 3 x 63A, 1x16a 1PH* | |
| PV input capacity (optional) | 5.5 / 11kWp | |
| PV input (DC) | 65-450VDC | |
| Noise level | TBCdBA @7M | |
| Weight | 4,200kg | |
| Dimensions (D x L x H) | 1180 x 2944 x 2137mm | |
*Output sockets can be customised


Technical specification:
| Output power from battery power | kW | 200 | ||
| Output power from battery power | kVA | 200 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 60 | ||
| Battery capacity | kWh | 249 | ||
| Passthrough current limit from main input | A | 250 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery Cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input Connection | A | 600A Powersafe | ||
| Output Connection | A | 600A Powersafe | ||
| Series Input Connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 60 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 6,282 | ||
| Dimensions | D x L x H mm | 2780 x 1950 x 2280 | ||
| Output power from battery power | 200kW | |
| Output power from battery power | 200kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 60kW | |
| Battery capacity | 249kWh | |
| Passthrough current limit from main input | 250A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery Cooling | AC - forced air | |
| IP rating | IP54 | |
| Input Connection | 600A Powersafe | |
| Output Connection | 600A Powersafe | |
| Series Input Connector | 1x 125A IEC60309 | |
| PV input capacity | 60kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 6,282kg | |
| Dimensions (D x L x H) | 2780 x 1850 x 2280mm | |


Technical specification:
| Output power from battery power | kW | 300 | ||
| Output power from battery power | kVA | 300 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 90 | ||
| Battery capacity | kWh | 374 | ||
| Passthrough current limit from main input | A | 400 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input connection | A | 2x 600A Powersafe | ||
| Output connection | A | 2x 600A Powersafe | ||
| Series input connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 110 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 9,204 | ||
| Dimensions | D x L x H mm | 3950 x 2050 x 2336 | ||
| Output power from battery power | 300kW | |
| Output power from battery power | 300kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 90kW | |
| Battery capacity | 374kWh | |
| Passthrough current limit from main input | 400A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery cooling | AC - forced air | |
| IP rating | IP54 | |
| Input connection | 2x 600A Powersafe | |
| Output connection | 2x 600A Powersafe | |
| Series input connector | 1x 125A IEC60309 | |
| PV input capacity | 110kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 9,204kg | |
| Dimensions (D x L x H) | 3950 x 2050 x 2336mm | |


Technical specification:
| Output power from battery power | kW | 400 | ||
| Output power from battery power | kVA | 400 | ||
| Output voltage | VAC 3PH | 380 / 400 / 415 | ||
| Input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | ||
| Series input max capacity | kW | 80 | ||
| Battery capacity | kWh | 499 | ||
| Passthrough current limit from main input | A | 550 | ||
| Battery nominal voltage | V DC | 832 | ||
| Operating ambient temperature | Deg C | -30 - +50 deg | ||
| Battery cooling | AC - forced air | |||
| IP rating | IP54 | |||
| Input connection | A | 2x 600A Powersafe | ||
| Output connection | A | 2x 600A Powersafe | ||
| Series input connector | A | 1x 125A IEC60309 | ||
| PV input capacity | kWp | 110 | ||
| PV min - max OCV | VAC | 200-1000 | ||
| Noise level | dBA @7M | 58 | ||
| Weight | kg | 12,000 | ||
| Dimensions | D x L x H mm | 4650 x 2300 x 2500 | ||
| Output power from battery power | 400kW | |
| Output power from battery power | 400kVA | |
| Output voltage | 380 / 400 / 415VAC 3PH | |
| Input voltage | 380 / 400 / 415VAC 3PH | |
| Series input voltage | 380 / 400 / 415VAC 3PH | |
| Series input max capacity | 80kW | |
| Battery capacity | 499kWh | |
| Passthrough current limit from main input | 550A | |
| Battery nominal voltage | 832V DC | |
| Operating ambient temperature | -30 - +50ºC | |
| Battery cooling | AC - forced air | |
| IP rating | IP54 | |
| Input connection | 2x 600A Powersafe | |
| Output connection | 2x 600A Powersafe | |
| Series input connector | 1x 125A IEC60309 | |
| PV input capacity | 110kWp | |
| PV min - max OCV | 200-1000VAC | |
| Noise level | 58dBA @7M | |
| Weight | 12,000kg | |
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | |

Technical specification:
| Model Variation | 624kWh | 1MWh | ||||
|---|---|---|---|---|---|---|
| Output power from battery power | kW | 500 | 500 | |||
| Output power from battery power | kVA | 500 | 500 | |||
| Output voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Series input voltage | VAC 3PH | 380 / 400 / 415 | 380 / 400 / 415 | |||
| Series input max capacity | kW | 80 | 80 | |||
| Battery capacity | kWh | 624 | 1040 | |||
| Passthrough current limit from main input | A | 630 | 630 | |||
| Battery nominal voltage | V DC | 832 | 832 | |||
| Operating ambient temperature | Deg C | -30 - +50 deg | -30 - +50 deg | |||
| Battery Cooling | AC - forced air | Liquid cooled | ||||
| IP rating | IP54 | IP54 | ||||
| Input Connection | A | 2x 600A Powersafe | 2x 600A Powersafe | |||
| Output Connection | A | 2x 600A Powersafe | 2x 600A Powersafe | |||
| Series Input Connector | A | 1x 125A IEC60309 | 1x 125A IEC60309 | |||
| PV input capacity | kWp | 110 | 110 | |||
| PV min - max OCV | VAC | 200-1000 | 200-1000 | |||
| Noise level | dBA @7M | 58 | 58 | |||
| Weight | kg | 14,194 | 14,194 | |||
| Dimensions | D x L x H mm | 4650 x 2300 x 2500 | 4650 x 2300 x 2500 | |||
Model variation: 624kWh
| Output power from battery power | 500kW | ||
| Output power from battery power | 500kVA | ||
| Output voltage | 380 / 400 / 415VAC 3PH | ||
| Input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input max capacity | 80kW | ||
| Battery capacity | 624kWh | ||
| Passthrough current limit from main input | 630A | ||
| Battery nominal voltage | 832V DC | ||
| Operating ambient temperature | -30 - +50ºC | ||
| Battery Cooling | AC - forced air | ||
| IP rating | IP54 | ||
| Input Connection | 2x 600A Powersafe | ||
| Output Connection | 2x 600A Powersafe | ||
| Series Input Connector | 1x 125A IEC60309 | ||
| PV input capacity | 110kWp | ||
| PV min - max OCV | 200-1000VAC | ||
| Noise level | 58dBA @7M | ||
| Weight | 14,194kg | ||
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | ||
Model variation: 1MW
| Output power from battery power | 500kW | ||
| Output power from battery power | 500kVA | ||
| Output voltage | 380 / 400 / 415VAC 3PH | ||
| Input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input voltage | 380 / 400 / 415VAC 3PH | ||
| Series input max capacity | 80kW | ||
| Battery capacity | 1040kWh | ||
| Passthrough current limit from main input | 630A | ||
| Battery nominal voltage | 832V DC | ||
| Operating ambient temperature | -30 - +50ºC | ||
| Battery Cooling | Liquid cooled | ||
| IP rating | IP54 | ||
| Input Connection | 2x 600A Powersafe | ||
| Output Connection | 2x 600A Powersafe | ||
| Series Input Connector | 1x 125A IEC60309 | ||
| PV input capacity | 110kWp | ||
| PV min - max OCV | 200-1000VAC | ||
| Noise level | 58dBA @7M | ||
| Weight | 14,194kg | ||
| Dimensions (D x L x H) | 4650 x 2300 x 2500mm | ||
Temporary power shouldn’t come with compromises
Relying solely on generator power for temporary sites often means falling foul of noise restrictions, fuel logistics, and costly downtime. For construction sites, event organisers, and pop-up community projects, that can create disruption exactly when you can’t afford it. Our intelligent, transportable Battery Energy Storage Solution reduces that reliance. By storing power on-site, it allows businesses to drastically reduce generator runtime — delivering quieter, cleaner, and more dependable power.
Applications of transportable battery energy storage systems
Film, media & broadcast
Silent, fume-free power for location shoots, broadcast sets and mobile production units.
Outdoor events & festivals
Keep stages, stalls and lighting running without noisy generators or refuelling headaches.
Construction & hire
From running power tools and site lighting to charging battery-electric construction equipment, transportable units are designed for temporary heavy-duty use.
Military
Deploy robust, wheeled, case-mounted or containerised systems to power up field operations, communications and surveillance.
Humanitarian & aid
Provide safe, reliable energy for emergency response hubs, medical tents and refugee sites.
Specialist applications
From telecoms to research expeditions, we design bespoke transportable systems for unusual power challenges.
Want to understand how renewables fit in? Explore our dedicated pages on Solar and Electrification to see how our battery energy storage solutions maximises clean energy.
The UK’s leading supplier in industrial-scale transportable energy storage (ESS)
Adopting new power technology can feel risky – but with our team, you’re not figuring this out alone. We’ve been at the forefront of battery energy storage solutions (BESS) for 30+ years, supplying advanced off-grid and transportable systems across the world. As one of the UK’s leading suppliers of hybrid power units, we assemble each transportable energy storage solution (ESS) using market-leading lithium-ion batteries and inverter technology. Our engineers have powered everything from construction mega-projects to temporary surveillance centres. We understand real-world challenges and design our transportable power units to be robust enough to withstand them.
Every Energy Solutions transportable battery unit uses industrial-grade components in a durable housing. From high-impact steel frames to digital battery management, we ensure your transportable unit performs reliably in tough conditions. Because we support our systems in the UK, you have a team of expert engineers on hand to advise on bespoke configuration from 15kVA through to 500kW, installation and monitoring.
Quieter, cleaner, hassle-free temporary power storage wherever you operate.
Built for the real world
Weatherproof, shock-resistant enclosures will keep you running on construction sites, festival fields, or any harsh environment.
Plug-and-play convenience
Each system comes pre-configured. Just connect your equipment and press start – no complex setup or technical expertise needed.
Flexible charging
Recharge from mains power, solar panels, or a generator on site. Our intelligent controller seamlessly manages inputs to keep you charged.
Smart generator integration
Use as a standalone unit or in hybrid mode: our BESS can automatically start/stop a backup generator to cover peak loads, saving fuel and wear.
Expert support
Our UK-based engineers are at hand to assist. We offer remote monitoring, routine maintenance, and friendly support to ensure your transportable BESS system operates flawlessly.
Trusted suppliers of battery energy storage solutions (BESS) to






How to get reliable movable battery energy storage
Our three-step process takes the stress out of upgrading your transportable energy supply:
Step 1
We begin with a detailed consultation to understand your load profile, site and transportation constraints and growth plans.
Step 2
Next we recommend the right EasyGrid plug-and-play solution for your needs. If needed, we can design and assemble a bespoke battery energy storage system pre configuring it to integrate with your existing power supplies.
Step 3
Finally, we deliver your system, train your team and provide ongoing monitoring so you enjoy quiet, efficient moveable power from day oneÂ
How our transportable BESS can help you stay powered and productive

Construction site night work – silent power, happy neighbours
Challenge: A UK construction firm faces strict noise curfews on an urban project
Solution: Using a transportable BESS would enable tower lights and CCTV to run off the battery unit from 10 PM to 5 AM, with need for just one hour’s generator use throughout. This could cut fuel use by 70% and significantly reduce disturbance to residents.

Community festival goes green – quiet, clean energy for public spaces
Challenge: A local council running a weekend festival wants to minimise noise and emissions from diesel generators powering food stalls and sound stages.
Solution: A transportable BESS could provide silent, fume-free electricity for vendors and performances when it matters, occasionally recharging from a small generator or the grid. The result: a significantly smaller carbon footprint, fewer noise complaints, and a more enjoyable experience for visitors.

Emergency response in the field – power when it matters most
Challenge: In a flood response scenario, emergency services need a reliable, moveable power source for command centres and communications towers.
Solution: A rugged transportable BESS could deliver 8+ hours of uninterrupted electricity for radios, lighting and laptops, even in harsh weather. With no refuelling issues to consider, responders could focus on the crisis while keeping operations running smoothly and quietly.
Transportable battery power you can count on, wherever duty calls
Relying on generators for temporary power isn’t just an inconvenience — it’s a liability. Constant noise, high fuel bills, continual refuelling, and unexpected breakdowns can put projects, operations, or events at risk. What’s more, they are increasingly at odds with sustainability goals, drawing criticism from stakeholders and regulators alike. With Energy Solutions’ transportable BESS, those worries are eliminated. You gain a professional, transportable power source that is quiet, clean, and dependable — avoiding 2 a.m. refuelling, event interruptions, and complaints about fumes or noise. Instead, you reduce emissions, lower fuel costs, and visibly demonstrate your commitment to greener, more responsible operations.
Get in touch with Energy Solutions today to discuss your transportable BESS needs and secure reliable power anywhere.
FAQs: Transportable battery energy storage solutions
Transportable battery energy storage systems (BESS) are transforming how UK businesses, events, and specialist operations access reliable temporary power. From construction sites to humanitarian projects, moveable BESS units deliver clean, quiet electricity where generators aren’t practical. Below, we answer the most common questions about movable commercial battery storage, including how it works, the benefits, and the industries best suited to adopt it.